Label Clearance at Crossings

This command check clearance of a crossing between any sewer network pipes, utility network pipe, and 3D pipe polylines. It displays clearance value, as well as the invert and crown elevations on the command line. Users can also label the results next to the crossing on screen.

From the Network > Check Sewer Network menu in the Hydrology Module, select Label Clearance at Crossings. In the drawing, first have all the networks drawn in plan view. Hovering over a pipe crossing in plan-view will give real time information on screen dialog box.

The Clearance Label Setup Dialog is used to draw the clearance labels on screen. The settings are saved and no need to bring it up next time to check and label clearance. Clear the Draw Labels box and the program won't label the results on screen.


Label Setup Dialog

                                                                                                                                                                       
Real Time Clearance Result Dialog Box on Screen




Clearance Result on Command Line


Clearance Labels on Screen

Pulldown Menu Location: Network > Check Sewer Network
Keyboard Command: label_clearance
Prerequisite: sewer network/utility network/3D pipe polyline crossings in plan view