The Edit Profile View command allows the user to select a
structure or a pipe on a profile and make fast, easy edits to a
sanitary\storm network (*.SEW). These edits will automatically
update the network file (*.SEW), update the profile drawn, and
update other design features such as Energy Grade Line (EGL) and
Hydraulic Grade Line (HGL) data as long as the user applies the
feature to Save to Profile File when drawing the profile
itself.
When making profile edits the user will select either a
structure or a pipe to edit. If a structure is selected the user is
allowed to make vertical edits to the selected structure. If a pipe
is selected the user will have the options to modify the pipe
invert in or invert out by selecting on the appropriate end of the
pipe, or by selecting the middle of the pipe to hold the pipe slope
and move the entire pipe for vertical revisions.
First select the structure to edit. The following dialog box
will open showing the Old Elev: and the New Elev: the user can then
enter new elevation or pick a point for elevation on screen.
Structures can only be edited in the profile vertically.
Select sewer entity to move (Enter to End):
Pulldown Menu Location(s):
Network
Keyboard
Command: sewer_prof_grip
Prerequisite: A sewer (.SEW) file and saved (*PRO) profile
pipes.